Appendix I Firmware Upgrade
Enter Setup
Download 3656
CPU Firmware
6) Run the download utility “ProgLoad.exe” on your computer.
Kernel Program
User Program
K3656_V*.shx STD3656_V*.shx
For the communication settings, select
“RS-232” and the correct COM port for
RS-232 or USB Virtual COM interface.
For RS-232, select 115200 bps for baud
rate; for USB Virtual COM, ignore the baud
rate setting.
For the file option, click [Browse] to select
the target file for firmware update.
Click [OK].
7) The 3656 will automatically restart itself when upgrading firmware is completed
successfully.
8) Read the “Update” barcode for the scanner to resume its operation (exit the
configuration mode).
Update